NEW HOME INSPECTION REPORT  

 (Punch-out Report)

                                                                                                                                         6/22/06                                                      

CLIENT

Mr. & Mrs. X

 

RESIDENCE LOCATION:

8052 ______ Avenue, Cincinnati Ohio 452xx

 

GENERAL INFORMATION:

As in all inspections, this report is based on visual observations of the residence. The inspection was made without removing any existing covering surfaces or materials.  If an area of the residence is inaccessible, it will be noted in the report. There is no warranty implied as to the value, life expectancy, fitness for particular function, usefulness, or merchantability, and therefore, FINEGAN INSPECTION SERVICES, INC. assumes no liability in those areas. All above conditions and those of the attached Inspection Agreement apply to this inspection unless in writing so noted by either party within 24 hours of receipt of this report via fax or mail.

   All observations are noted as the inspector faces the front of the house for purposes of mutual orientation.

   This is a punch list report so as to review the items in the house that are in need of repair or to be finished by the builder as a part of the final walk through process. The inspection was made on 6/19/06 between 1:00 p.m. and 4:20 p.m.

  The information is made available to           only and is held in confidence. The information in this report is not prioritized but a set of repairs and modifications necessary so as to comply with Warren County and N.E.C. codes and Industry Standards Manual of the Home Builders Association of Greater Cincinnati. The information should be reviewed by the interested persons as a basis for repairing and adjusting components of the home. Those items that are not recognized as “workmanlike” will be so noted.

   The term workmanlike refers to common and acceptable methods of construction technique and/or protocol in a particular area. This list does not take the place of any other repair list provided by the owner or any other person, but rather is intended as a guide to accomplish the finish of the house as per normal workmanlike construction techniques.

  Any or all agreements made between the owners and the builder that were supplemental to the contract and that may affect the construction technique are not addressed in this report.

   Special Note: Any items that should be repaired by the builder will be marked *** prior to the comment. Other items are suggestions to the homeowner or discussion of items relative to the construction of the home.

  RECOMMENDATIONS &  OBSERVATIONS

  There were items on the interior and exterior of the home that need adjustment or repairs to the finishes details.  Most are typical “punch out items that are found in many new homes. The following items are so noted. The homeowner will have a list of items as well. This report does not take the place of the homeowners list. It is intended as a supplement to any such list:

 Roof    

  The upper roof and the lower roof were inspected from the roof surface level and from eave line level.

  1). The inspection found no problems with the installation of the roofing shingles. There were good quality fiberglass composition shingles that were secured in a workmanlike fashion. A few other items that were inspected are noted below;

***    a).  The torn shingle at the right hip ridge of the second story eave line is recommended for replacement.

  ***     c).  Application of a roofing cement on all the exposed nail heads on the roof surface is recommended. The ridge vent, box vents, boot flashings were all recommended for the sealant application.

     

  ***2). There were a few modifications to the upper roof surface. The following items were noted.

        a). Remove any of the stray nails that are on the shingle surfaces at this roof surface.

     3). The gutters were noted to be in good general condition. Due to the volume of trees in the area a gutter guard of some type is strongly recommended. There are many types and many manufacturers. Have these installed as soon as possible. The trees with seed in the spring and these can block a gutter and downspout system.

     4). The rest of the flashing systems were noted to be installed on this home in a workmanlike fashion. The flashings are metal sections that seal any potential gaps in the roof systems at intersection points of the roofs and other components.

           5). There is a chimney system located on the top roof system. The metal chimney is noted to be installed for the master bedroom gas fireplace system. The metal vent that is located at the rear of the upper roof was noted without problems.

     6). The venting system on this roof system was noted to be a ridge vent system and a box vent system. Both of these are “passive” vent systems. There was also an attic fan. It was tested and functioning properly. The passive vents were installed without problems noted. 

Exterior Walls & Exterior Trim              

 7). There were brick and vinyl siding surfaces on the exterior wall façade of this home. The installation and siding and brick were in good general condition with only a few punch out modifications recommended. The following items were noted on the exterior building envelope of this home:

 a). There were noted a very good quality of exterior envelope component installation. The trim was secure and properly fitted to the wall corners, frieze boards, rake boards and the soffit areas.

      The brick has the proper volume of weep holes and there were a few that were randomly checked. None were uncultured with mortar. All were clear of debris and the foundation seal was observed in all locations where the weeps were inspected.

 *** b). The overhead door trim around the garage door needs to be modified. There was a gap between the weather seal trim and the side jambs this location.

    Seal this gap

        c). The application of a parge coating to the surface of the exposed foundation on the left rear of the home is suggested. There are several cementitious paints on the market to add color and texture to the concrete foundation wall surfaces.

 *** d). The rear transom window needs the caulking between the steel lintel and the top of the window frame.

The sealing of this gap is needed.

Text Box: Caulk the gap at the top of this window

                   

*** e). The brick surface at the rear of the home has some mud on the brick surface that is recommended to be washed off. There were no issues with the installation of the brick façade, the mortar nor were there any visible chips or gaps in the brick or the mortar. The façade is of good quality. Text Box: Wash this surface

  

SITE CONDITIONS  

 8). The final grade is accomplished, the finish soil grade of all planting beds should always be kept lower than 3” from the bottom of the brick and the vinyl surfaces in the future. All mulch and planting beds should be kept lower than that level in all locations so as to allow proper “fall” of the soil grade away from the foundation and to prevent any termite or carpenter ant access.

At this time the soil grade at the rear of the home was close to the brick. Keep a gap between the mulch and the brick at this rear location.

Text Box: Keep a gap between the soil and the brick here

 

9). The driveway masonry surface is in good condition, what could be observed. Use a water sealant on the surfaces in the future is suggested. The application of Weather X or Enviro Seal is recommended because these are good products. The color differential should slowly bleach out as the sun dries the surface through to the core of the slab. 

 *** 10). The downspouts terminate into conductor lines. The drainage of these lines appears to terminate in the rear of the lot. The conductor lines and the general surface water drainage of the site is of good quality.

 

GARAGE  

         

 11). There was an attached garage on this new home. The garage was noted to have all surfaces that are in contact with the interior walls of the home, drywall covered.   The garage walls were noted to be in good general condition as could be observed at the time of the inspection. 

               b). The overhead garage door has the opener installed; the down force pressure on the openers should be adjusted so that it will reverse on resistance.  Also, have the manual locks need to be removed from the doors.

               c). Note that the GFCI outlets are re-set in the garage for the sake of convenience. All were tested and functioned.

      d). The garage slab was inspected. There were no significant issues noted with the surface at the time of the inspection.

               e). The garage steps up and into the home were noted. The rise differential and the tread width and depth appeared to be in conformance with the normal building code requirements.

              f). There is an attic over the garage and it was inspected. The truss system, vent system, and all other building components that compose this attic system are of good quality.

            ***  g). The fire door that separates the garage from the interior of the home will need the pressure closer activated.

 

INTERIOR

 

 *** 12). In the kitchen the dishwasher was noted to be properly secured to the counter top and the disposal was tested and had no problems. The ovens and cook top were functional at the time of the inspection. The vent hood above the cook top was noted to have proper operation. The microwave was properly operational.

 13). The mud room/ laundry were inspected. The floor, walls and other interior surfaces were in good condition. There was a laundry tub. It was secured and functional. The water supply connections were not tested at the wall box.

    In the future, be sure that the water supply hoses that supply the washing machine are composed of the flex steel type. These will have a far lower potential to burst.

     Be sure to clean the lint from the dryer vent every year to avoid blockage or fire.

   a). The exterior door in this mud room operates smoothly. It was suggested that a storm door be considered at this door because it is a west facing door which is subjected to higher winds and rain.

 14). All interior paint touch ups, floor finishes and drywall touch ups were not yet accomplished at the time of the inspection. The home buyers will be responsible for the drywall and paint issues. This inspection company does not involve itself in aesthetic issues.

   *** a). Be sure to cut the interior doors up and off the carpet by an inch so that the carpet surface is not worn in the swing pattern of the door. In the second story closet at the left side hallway a trimming of the door is recommended.

   *** b). The floors need to be cleaned and finished. There were no problems noted with the installation of the various components. The hardwood in the kitchen appears to be ready for a final coat of polyurethane.

     *** c). The master tub needs the caulking of the tub lip at the intersection point with the top surface of the deck and the cover placed on the tub motor access.

 Before using the whirlpool tub, be sure to fill it and then run it for 20 minutes with 3 cups of bleach and a typical amount of dishwasher detergent poured into the water in the tub. This will clean the lines and keep them disinfected.

Text Box: Caulk here

  

15). Do buy a few Night Hawk carbon monoxide detectors and place them in the house as per recommendations by the manufacturer. There were no leaks or carbon monoxide leaks at any appliance or mechanical equipment where they were tested in the basement   

 16). The cleaning of the faucet and the aerators is needed in the house now and again in the next 6 months into the future. This is because the screens and restrictors in the faucets often become clogged with dirt and debris that was inside the copper lines when they were installed.  The water pressure was at a level where there should be no low flow in this house.

  17). The fireplaces in the family room and master bedroom were functional at the time of the inspection. There were no gas or monoxide leaks detected.

 18). The windows in the house were noted to be a vinyl single hung type. The operation of every single unit was not accomplished. A representative sample of every room was accomplished. The windows were noted with no modifications needed at this time.   A silicone spray application to the side jamb tracks is recommended.

 19).  A penetrating grout sealant application to the grouting in the bathrooms & on any or the entire floor tile and the wall tile grout was strongly recommended.

  ***20). In HVAC supply ducts at the floor “boot” sections there was some construction dust noted in the base of the ducting. Have this dust/dirt vacuumed out of the ducts. Be sure that the cleaning crew cleans the bottoms of the “floor boots” of the duct system.

    The supply vents and the return vents in the HVAC system could not be completely inspected due to the finished nature of the home. There were no areas that were observed with low or poor air flow observed

  ATTIC 

  21). The insulation in the main attic was in good condition. The proper R value appears to be accomplished in the entire attic system. There were no observed problems with the insulation system over the ceiling.

       22).   The venting of the upper attic appears to be sufficient at the apex of the attic space and at the soffit areas. The air passages at the attic areas near the truss bearing points were clear of insulation and blockage. The air passages had baffles installed at the soffit area of the attic. 

  23). The roof structure was composed of standard trusses. The truss system showed no areas where any departures from standard installation and construction technique were observed. There were no broken or damaged framing components observed at the time of the inspection. The truss system is an engineered product. There were no engineering drawings observed to arrive at this conclusion. The trusses were only visually inspected. No load calculations were accomplished as a part of a punch out inspection.

 *** 24). There was an open electrical box on the side of the truss that is next to the access opening. Have this box sealed or a light fixture installed.

   MECHANICAL    

 *** 24). The air conditioning was not tested. This is because the exterior compressor needs to be checked by the installation contractor. Be sure that the installation contractor starts up the system. He must check the refrigerant level prior to start up. Be sure that the exterior coils on this air conditioner are kept clean and free of dirt and debris.

 25). The furnace was noted to be a “90 +” type. The efficiency of these furnaces is very good. The important items to remember concerning the operation of these units is to be sure that the condensate drains properly into the floor drain. Because these units produce a great deal of condensate with in operation, and because the condensate is VERY caustic, the proper drainage of this water out of the furnace compartment and through the drain tube and into the floor drain is imperative.

  Remember that there are 5 things to check if the furnace/air conditioner does not work:

           1). The fuse in the circuit board in the blower chamber.

           2). The door to open the blower chamber must be secure and snapped into place. It has a “dead man” switch that will prevent the unit from operation if the door is not secure.

           3). There is an ON/OFF switch next to most units. Check to see if the switch has accidentally been turned off.

           4). Check that the breaker in the electrical panel is on. There will be one labeled as “FURNACE” on the directory sheet that is glued to the inside of the door that accesses the breakers.

           5). Check the thermostat to be sure that all settings are correct and the unit is in the proper mode of operation.

 26). Cleaning of the air filter in the furnace is needed every week for the first month or two to remove the volume of construction dust inside the system.

                 27).  The electrical panel is noted to be in good condition. There is proper wiring of the box and room for future expansion in terms of space and available amperes.

      Note that there are breakers in this panel that are marked as AFCI. This stands for Arch Fault Circuit Interruption. These have a yellow re-set button on the breaker. Notice that they are connected to the bedrooms in the home. The reason for the installation of these types of breakers on circuits that are to the bedrooms is because that is where we are most vulnerable.

      The AFCI breaker is intended to prevent a circuit to which it is connected from overheating if a wire in that circuit is not secure where it connects to a switch or an outlet or a fixture. These new breakers are required by the National Electrical Code. If they should trip to OFF, have an electrician called in immediately and leave the breaker in its OFF position. When these breakers trip to off there may be an “arching” at the connection point of the electrical wire to the outlet, fixtures or switches that are on that specific circuit.

BASEMENT        

 

   28). There is a sump pump.  The crock was not observed because it was sealed. A battery back up is always recommended on any sump pump system. Test it regularly.

   29). The foundation was a cast-in-place type. The foundation showed no evidence of problems with its construction or the materials.

    30). The concrete slab had typical cracks in the surface. There were no areas where the concrete slab showed evidence of problems

    31). The floor joists that were observable were noted to be installed without problems. The spans and dimension of the lumber used to construct the floor system are consistent with other new construction.

    32). The sub floor was composed of plywood. The sub floor was observed from the underside. The condition was noted to be in good condition. Support for the sub floor was consistent with standard residential construction techniques. No building plans were used to arrive at this conclusion, only past experience with new construction methodology.

   Wherever there are openings in the sub floor there should be a fire stop rock wool installed so that there is no “chase” for fire. Above the main electrical panel a rock wool installation is needed at the hole that allows the branch wires of the electrical circuits to pass through the floor.

Text Box: Seal the hole with rock wool here

 

    33). The basement stair system was inspected and found to be functional. The treads and rise distances were good. The stringers and the treads were consistent with other residential construction techniques observed by this firm.

  34). The window systems in the basement were noted to be typical window types. There were no cracked or damaged window panes and the sashes were square and the units were functional.

   35). The steel I beams and posts were inspected. There was no evidence of problems observed. The exact location of the post placement and the beam size was not a calculation that is accomplished as a part of a visual based punch out inspection. The builder and the engineer that designed this home are responsible for those areas.

     Thank you for using Finegan Inspection Services, Inc.  Please call if there is anything we can assist you with in the future.

             

FINEGAN INSPECTION SERVICES INC.

 

 by Terrence P. Finegan

 American Society of Home Inspectors certification #033511

  E-mail- terry@ fineganinspectionservices.com

 

Back to Top

Terrence P. Finegan
Certified Member of the American Society of Home Inspectors, #033511.
Certified Member of the Exterior Design Institute, OH-17
 
Scott Jones
Certified Member of the American Society of Home Inspectors, #210942
 
Paul Jackson
Certified Member of the American Society of Home Inspectors
 

Moisture Warranty Corporation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 Designed & managed by @nthropology design: email
Copyright © 2007-2008 Finegan Inspection Services, Inc.