FOR
Mr. and Ms.
X
4/29/05
RESIDENCE
Cincinnati, Ohio
GENERAL:
As in all inspections,
this report is based on visual observations of the residence. The
inspection was made without removing any existing covering surfaces
or materials. If an area of the residence is inaccessible, it will
be noted in the report. There is no warranty implied as to the
value, life expectancy, fitness for particular function, usefulness,
or merchantability, and therefore, FINEGAN INSPECTION SERVICES, INC.
assumes no liability.
This is a maintenance
review inspection report, which is designed to discuss the interior
and exterior conditions of the house and building components at the
above noted residence. A maintenance review is intended to highlight
items that need to be repaired, modified or adjusted as part of
normal home maintenance. Items that were observed for repair on this
house will be broken out in a format that details the following 10
areas:
1). Roof, shingles,
chimney systems, gutters and flashings.
2). Exterior walls and
trim.
3). Site conditions.
4). Garage area and door
systems
5). Attic areas.
6). Plumbing waste and
supply lines and related piping systems.
7). General electrical
conditions.
8). Framing and structure.
9). H.V.A.C. system
including the air conditioning and the furnace systems.
10). Fireplace systems and
related venting systems.
All observations are made
as the inspector faces the front of the property for a point of
mutual orientation. Right and left will be noted rather than
East/West/North and South.
SPECIAL NOTE: This is a
limited type of inspection. It is not intended to be as detailed as
a full home inspection. The maintenance inspection is visually
based. See the attached inspection agreement. Only those items that
were noted to need repair, adjustment, modification or replacement
at the time of the inspection will be noted in this report. Photos
will be provided as needed.
OBSERVATIONS:
#1). Roof Conditions
There were a few items on
the roof surface that were recommended to be modified.
a). A drip edge flashing
installation on the right side roof surface of the garage, at the
eave line is needed. The shingles barely cover the gutter boards at
this area. The roof water may access behind the gutter board in the
future if this area is not better sealed. See Photo #1 and #2.
b). At the front center
gable roof and the front garage roof surface there were rounded
metal vents on the roof surface. The metal that was used to create
the rounded surface is starting to rust and needs to have a rust
inhibiting paint applied to the surface so that there is no pitting
to the metal in the future. See Photo #3
c). There is some type of
toy in the rear left second story downspout on the upper roof gutter
system. Have this item removed from the gutter area. See Photo #4.
d). There is a torn cap
shingle on the roof ridge over the second story room that is above
the garage. Seal the cracked shingle with roofing tar at this and a
few other cap shingle locations.
e). At the rear chimney
there was no diverter flashing at either side of the chimney EIFS
system. This is the cause of the moisture access into the substrate
at this location. See Photo #5.
f). There was some impact
damage to some shingles on the roof surface. None of the damage is
significant enough to warrant a new shingle layer installation. The
longevity of the existing layer, in this inspector’s opinion, is
not significantly impacted.g). Seal the box vents at the ridge of
the rear roof where there were a few gaps on the side of the vents
at the shingle lines. See Photo #6.
h). Modification of the
rear porch roof flashing is needed at the EIFS intersection of the
roof surface and the rear house wall.
#2). Exterior walls and
Trim
a). All windows have a
sill extension at the exterior bottom sill area. The small gaps that
develop at these areas often times are the cause of moisture access
at the window frame areas. Even a very small gap can be a source of
moderate water infiltration into the wall cavity on these types of
windows. In Photo #8 at the front dining room, there is a small gap
at this location. Seal the gap with caulking and check all windows
at these intersections.
b). The front stone
façade was installed on top of the sidewalk to the right of the
front steps. The sidewalk has moved slightly as a result and has
allowed a gap to develop at the top of the short wall. Water will
surely get behind the wall in the given condition. A “cap” block
is recommended to be installed. The gap should be properly sealed.
See Photo #9.c). Seal the steel lintels at the front stone wall to
prevent rust, expansion and mortar cracking. See Photo #11.
d). There is a storage
room under the rear deck. It was noted to need modification of the
EIFS system. There was water leaking into the substrate at the rear
wall of the storage room, near the rear pier of the deck post. See
Photo #12
e). Exterior trim painting
should not be needed for another 2 years.
#3). Site Conditions
a). The site conditions
were mostly in good condition. Be sure to keep the mulch level and
landscaping sufficiently away from the wall surfaces and the bottom
of the EIFS. 4” to 6” is a good distance.b). The landscaping
lighting was damaged in the front planting beds and needs to be
repaired. There was frayed wires noted at the center light. See
Photo # 7.
c). Tuckpoint the mortar
gaps at the front steps. See Photo # 10.
#4). Garage areaa). The
electrical outlet in the garage is a GFCI. There was noted a
refrigerator plugged into the GFCI. It is recommended that the
refrigerator be removed from the GFCI outlet and circuit and placed
in a dedicated circuit. This will prevent a shut off of the power.
b). Adjust the garage door
openers so that there is a better sensitivity of the downforce
sensitivity on each opener. Presently the openers did not reverse on
resistance.
c). Disable the overhead
garage door locks on the overhead doors.
#5). Attic area
a). There was very low
insulation in all attic areas. Another 6” needs to be added to the
entire attic area. On the second story attic, above the rear left
bedroom, there was a large gap in the insulation due to someone
moving the insulation out of the ceiling area in that attic
location.#6). Plumbing
a). There was a gas range
in the basement that was tested for monoxide levels at the time of
the inspection. The range was tested 3 times and monoxide levels
were consistently above 300 ppm when the range oven was in
operation. This is a very dangerous condition. Do not use this range
until a professional in appliance repair can further investigate.The
burner was cleaned and the flame level was lowered by a appliance
person and the monoxide levels were lower on the second visit to the
house on January 29, 2003. The appliance repair individual stated
that 300 ppm is not dangerous. This is an incorrect statement. Any
level over 30 ppm should be treated as a hazardous condition.
b). Water pressure was
noted to be at 80 p.s.i. This is a moderately elevated level of
water pressure and it is recommended that it be reduced to a 70
p.s.i. level.
c). Sump Pump- The sump
pump was full of debris and needs the bottom of the crock cleaned
out. The addition of a battery back up sump pump is recommended for
installation in the sump crock.
d). Both water heaters
were tested and noted to be free of elevated monoxide levels and
were functioning as intended. There were no gas or water leaks
discovered in either unit.
#7). Electrical Conditions
a). There were no problems
noted in this electrical system.
#8). Framing/Doors &
Windows
a). There needs to be a
latch adjustment of the rear sliding door that is on the rear wall
from the television area.
b). There were no welds at
the post/beam intersections in the unfinished portion of the
basement. Through bolts were recommended at these locations.
#9). H.V.A.C.
a). On the exterior of the
house there was the cooling unit noted on the right side. The unit
had significant volume of dirt inside the condensing coils inside
the cabinet. The removal of all panels and the cleaning of all coils
on the cooling system is needed.
b). The interior
evaporator coils are probably dirty as well. There is no evidence
that they have ever been removed from the interior plenum in the
past 10 years. At this juncture the interior evaporator coils must
be pulled and cleaned at the tray cleaned. There is evidence that
the tray is leaking condensate water over the interior of the
furnace heat exchanger and interior of the furnace compartment.
c). The furnace needs to
be cleaned and the affected components repaired/cleaned/replaced as
needed. The “A-Coil” needs to be cleaned.10). Fireplace Systems
a). There was no problems
with the fireplace units. The basement unit was noted with a smell
caused by the burning off of the paint and manufacturing oils. Open
the windows and run the unit for a few hours a day for a week at the
smell should stop.
b). Do install new Night
Hawk smoke/monoxide detectors in all levels of this house.
Thank You for using
Finegan Inspection Services, Inc. ASHI Member #033511Please do not
hesitate to call if there is anything we can assist you with in the
future.
FINEGAN INSPECTION
SERVICES INC.
ASHI Certified
Inspector #033511
by Terrence P.
Finegan
Phone: 513-683-0733